Micro detection in Perfection
For us no leak is too small: the forming gas
method.
All kinds of piping systems and containers
can be inspected for leackages with the forming gas method.
Therefore a special sample gas will be inserted into the conduit / the
tank. The sample gas will leak from the defect location and rises
perpendicularly to the top.
With the micro detector the amount of gas and the concentration can be
measured at the surface.
(As well internally as in the outer area)
This way an exact localisation of the defect spot is possible without
prior work to uncover the faulty spot.
Application Areas:
Home installations e.g.:
- heating and cooling systems
- floor heatings
- water conduits
- pipe systems in general
Pipeline Constructions e.g.:
- pressure test negative
- gas-, water- district heating pipeline
- tank construction
- refueling facilities
Scope of delivery:
- leather bag
- riser
- rubber insert
- recharger
Display:
LCD-Display with numeric and graphic display of volume
Alarm threshold possible at any setting
Measuring ranges: PPM and volume %
Power supply: rechargeable Ni-MH-Accus without memory effect.
Operatimg time: aprrox.. 8 hours at continuous operation
Operating temperature: -10° C up to + 40° C
Weight: approx. 2.0 kg (without probe heads)
Dimensions: 200 x 80 x 120 mm length x height x width
Price idea EUR 2,100 per unit
ex warehouse plus VAT (if applicable) subject
to prior sale!